Rheem - Classic Series 5 Ton 17 SEER, Two-Stage, Non-Communicating, ECM Motor, Air Conditioning Split System

This Product Qualifies For FREE US Shipping

9380
Rheem
In stock ships within 24 to 48 hours
Brand New
Free Shipping
CALL FOR PRICE AND AVAILABILITY

 RA17 Series (Non-Communicating) - Classic® Two-Stage Air Conditioners

  • New composite base pan - dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed
  • Powder coat paint system - for a long lasting professional finish
  • The Two Stage Copeland Scroll™ UltraTech™ Compressor modulates between two capacity settings - 67% and 100% - providing more precise temperature control, lower humidity and greater efficiency in comparison to single stage compressors. It uses 70% fewer moving parts which also increases efficiency and reliability.
  • Modern cabinet aesthetics - increased curb appeal with visually appealing design
  • Curved louver panels - provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity
  • Optimized fan orifice - optimizes airflow and reduces unit sound
  • Rust resistant screws - confirmed through 1500 hour salt spray testing
  • PlusOne™ Expanded Valve Space - 3"-4"-5" service valve space - provides a minimum working area of 27 square inches for easier access
  • PlusOne™ Triple Service Access - 15" wide, industry leading corner service access - makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly
  • Diagnostic service window with two-fastener opening - provides access to the high and low pressure.
  • External gauge port access - allows easy connection of "low-loss" gauge ports
  • Single-row condenser coil - makes unit lighter and allows thorough coil cleaning to maintain "out of the box" performance
  • 35% fewer cabinet fasteners and fastener-free base - allow for faster access to internal components and hassle-free panel removal
  • Service trays - hold fasteners or caps during service calls
  • QR code - provides technical information on demand for faster service calls
  • Fan motor harness with extra long wires allows unit top to be removed without disconnecting fan wire.
  • High and low pressure standard on all models.

RH2T- Series, EcoNet™ Enabled, Constant Torque Motor (ECM), Electronic Expansion Valve (EEV), Efficiencies up to 17 SEER.
RH2T Features:
  • Equipped standard with an EcoNet™ Air Handler control board that allows it to directly communicate with the EcoNet™ Control Center. The EcoNet™ Control Center serves as the hub of communication for a home's Heating, Cooling, and Water Heating systems, and is required to operate an EcoNet™ Enabled Heating and Cooling system in fully communicating mode. An EcoNet™ WiFi kit can be added to the EcoNet™ network and will use the homeowner's wireless network and broadband Internet connection to enable remote operation of EcoNet™ Enabled equipment from the mobile-friendly web portal or mobile apps.
  • Equipped with an electronic expansion valve (EEV), which can intelligently change the EEV position based on system demands. By the measurement of the suction pressure via the vapor line pressure transducer (factory installed) and the vapor line thermistor (field connected to the vapor line, but factory provided within the air handler) the EcoNet™ enabled air handler control calculates the suction superheat at the indoor coil. This calculation permits the air handler control to make decisions for when to open and close the EEV for the purpose of maintaining a predetermined suction superheat. The EEV is equipped with a 4-pole removable external stator, and inlet and outlet chatleff fittings for optimal serviceability. These valves also have an internal check valve to provide heat pump compatibility. When operating in heating mode, the air handler control will open the EEV completely to permit the check valve to operate and maximize reverse refrigerant flow.
  • The RH2T features a Constant Torque Two-stage motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units.
  • Evaporator is constructed of aluminum fins bonded to internally grooved aluminum tubing.
  • Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
  • Factory-installed indoor coil.
  • Sturdy cabinet construction with 1.0 inch [25.4 mm] of foil faced insulation for excellent sound and insulating characteristics.
  • Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L. and cUL requirements for service disconnect.
  • 11/2 ton [5.3 kW] through 5 ton [17.6 kW] models are between 421/2 to 57 inches [1080 to 1448 mm] tall and 22 inches [559 mm] deep.
  • All models meet or exceed 330 to 400 CFM [156 to 189 L/s] per ton at .3 inches [.7 kPa] of external static pressure.
  • Enhanced airflow up to .7" external static pressure.
  • Suitable for application in mobile homes.
General Terms Of Limited Warranty
  • Conditional Parts (Registration Required): Ten (10) Years
  • Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
  • See warranty certificate for complete details.
  •  
 

 

ERP ID 381035
Weight 291.000000
Locked Rotor Amps 152.9
Number of Fan Blades 1
Inverter No
Liquid Line Size (OD) 3/8"
Full Load Amps 5.3
Height 51.000000
Phase Single
Length 35.750000
Liquid Line Fitting Sweat or Braze
UL Listed Yes
Tonnage 5
SEER 17
Sound Level (dBA) 76.7
Suction Line Size (OD) 7/8"
Suction Line Fitting Sweat or Braze
Stages Cool 2
Stage Two
Package Height 51.000000
Warranty Offered Yes
Package Length 38.380000
Package Weight 291.000000
Package Width 38.380000
Product Family RA17
Width 35.750000
Voltage 208-230 VAC
Refrigerant R-410a
UPC 662021421310
UOM EA
Rated Current Amps 60
Rated Load Amps 28.8
Circuit Breaker - Min Amps 42
Circuit Breaker - Max Amps 60
CFM 5133
Certifications AHRI Standard 210/240, ISO 9001:2015
Condenser Motor HP 1/2 HP
Brand Rheem
Compressor Scroll
Equipment Type Straight Cool
Fins per Inch 22
Energy Star Rated Yes
Cubic Measurement 37.720600
Cooling Capacity 60000
EER 13
Cycle/Hertz 60 Hz
Dimensional Weight 530.000000

 

 
 
ERP ID 356258
Weight 161.000000
Liquid Line Fitting Sweat or Braze
Liquid Line Size (OD) 3/8"
Height 55.500000
Length 21.687500
UL Listed Yes
Tonnage 5
SEER 16
Suction Line Size (OD) 7/8"
Suction Line Fitting Sweat or Braze
Stage Two
Refrigerant R-410a
Phase Single
Warranty Offered Yes
Package Height 55.750000
Package Length 25.310000
Package Weight 178.000000
Package Width 27.500000
Width 24.500000
Voltage 208-240 VAC
UPC 662021392191
UOM EA
Product Family RH2T
Brand Rheem
CFM 1400, 1400-1800
Certifications ABS Quality Evaluations, Inc. Management System Certification, ISO 9001:2008 Certified
Circuit Breaker - Min Amps 5
Filter Size 25" x 20" x 1" or 2" on Rheem external filter base
Blower Motor HP 3/4 HP
Air Flow Convertible
Circuit Breaker - Max Amps 15
Blower Motor RPM 300, 300-1300
Drain Connection Size 3/4"
Equipment Type Electric Heat / Cool
Energy Star Rated No
EAN 0662021392191
Drain Connections 2
Dimensional Weight 283.000000
Cooling Capacity 60000
Cubic Measurement 17.065700
Cycle/Hertz 60 Hz